Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Int J Lab Hematol ; 46(1): 72-82, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37746889

RESUMO

INTRODUCTION: Mindray MC-80 is an automated system for digital imaging of white blood cells (WBCs) and their pre-classification. The objective of this work is to analyse its performance comparing it with the CellaVision® DM9600. METHODS: A total of 445 samples were used, 194 normal and 251 abnormal: acute leukaemia (100), myelodysplastic syndromes/myeloproliferative neoplasms (33), lymphoid neoplasms (50), plasma cell neoplasms (14), infections (49) and thrombocytopenia (5). WBC pre-classification values with the MC-80 and DM9600 were compared with (1) the microscope, (2) Mindray BC-6800Plus differentials in only normal samples, and (3) confirmed or reclassified images (post-classification). Pearson's correlation, Lin's concordance, Passing-Bablok regression, and Bland-Altman plots were used. Sensitivity, specificity, positive (PPV) and negative (NPV) predictive values for abnormal cells using the MC-80 were calculated. RESULTS: The PPV and NPV were above 98% and 99%, for normal samples. For immature granulocytes (IG), NPV and PPV were 100% and 74.2%. When comparing the WBC differentials using the MC-80, the microscope and the BC-6800Plus, no differences were found except for basophils and IG. Our results showed good agreement between the pre- and post-classification of normal WBC, including IG, quantified by high correlation and concordance values (0.91-1). Sensitivity and specificity for blasts were 0.984 and 0.640. The MC-80 detected abnormal lymphocytes in 30% of the smears from patients with lymphoid neoplasm. Plasma cell identification was better using the DM9600. The sensitivity and specificity for erythroblast detection were 1 and 0.890. CONCLUSION: We found that the MC-80 shows high performance for WBC differentials for both normal samples and patients with haematological diseases.


Assuntos
Leucemia , Leucopenia , Humanos , Contagem de Leucócitos , Leucócitos , Plasmócitos
2.
Clin Chem Lab Med ; 60(11): 1786-1795, 2022 10 26.
Artigo em Inglês | MEDLINE | ID: mdl-36039597

RESUMO

OBJECTIVES: Cellular analysis of body fluids (BF) has clinical relevance in several medical conditions. The objective of this study is twofold: (1) evaluate the analytical performance of the BF mode of Mindray BC-6800 Plus compared to manual counts under microscopy and (2) analyse if the high-fluorescent cell counts provided by the analyser (HF-BF) are useful to detect malignancy. METHODS: A total of 285 BF was analysed: 250 corresponding to patients without neoplasia and 35 to patients with malignant diseases. Manual differential counts were performed in BF with ≥250 cells/µL. Percentages and absolute counts were obtained on the BC-6800Plus for total nucleated cells (TC-BF), mononuclear, polymorphonuclear and HF-BF. Statistical analysis was performed using Mann-Whitney U-test, Spearman's correlation, Passing-Bablok regression, Bland-Altman graph and ROC curve. RESULTS: To compare manual and automatic total cell counts, samples were divided in three groups: <250, 250-1,000 and >1,000 cells/µL. Correlation was good in all cases (r=0.72, 0.73 and 0.92, respectively) without significant differences between both methods (p=0.65, 0.39 and 0.30, respectively). The concordance between methods showed values of 90%. Considering malignant samples, median HF-BF values showed significant higher values (102 cells/µL) with respect to non-malignant (4 cells/µL) (p<0.001). The cut-off value of 8.5 HF-BF/µL was able to discriminate samples containing malignant cells showing sensitivity and specificity values of 89 and 71%, respectively. Considering both, HF-BF and TC-BF values, sensitivity and specificity values were 100 and 53%, respectively. CONCLUSIONS: This study reveals that the Mindray BC-6800Plus offers an accurate and acceptable performance, showing results consistent with the manual method. It is recommended to consider both HF-BF and TC-BF values for the screening of the microscopic evaluation to ensure the detection of all malignant samples.


Assuntos
Líquidos Corporais , Hematologia , Neoplasias , Contagem de Células , Exsudatos e Transudatos , Humanos , Neoplasias/diagnóstico , Curva ROC , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...